Lead Sampling and Analysis
 

Lead Sampling and Analysis

Sample Type
Drinking
Water
Ghost
Wipes 1'x1'
Air
Soil
Paint Chips
TCLP
STLC
Sampling Techniques
250 mL high density Polyethylene bottle preserved with HNO3 to pH<2

Ghost Wipes, 1"x1", stored into a clean centrifuge tube

0.8 mm cellulose ester membrane, 37 mm cassette, 1-4 LPM for Personal & 10 LPM for Area sample
One cup soil in a centrifuge tube, brass tube or a plastic bag
One teaspoon of paint, sealed in a plastic bag or a centrifuge tube
Minimum of 100 g or 4 oz of sample in a jar or a plastic bag
Minimum of 50 g or 2 oz of sample in a jar or a plastic bag
Analytical Methods

GFAA

EPA 200.9

FLAA

NIOSH 7082

FLAA

NIOSH 7082

OSHA ID-121

GFAA, NIOSH 7105

FLAA

EPA SW-846

FLAA

ASTM E1645-01

FLAA

EPA SW-846

EPA 1311

FLAA

California Code of Regulations

Title 22

Reporting Limit
5mg/L
10 mg/sample
2 mg/sample
10 ppm
50 ppm
0.5 mg/L
0.5 mg/L
Action Level
15 mg/L
EPA Clearance: 40 mg/ft2
PEL: 50 mg/m3
Ambient soil: <200 ppm
HUD: 5000 ppm
5 ppm
5 ppm
MCL: 50 mg/L
Window sills: 250 mg/ft2
AL: 30mg/m3
Title 22: 1000 ppm
CPSC: 600 ppm
Window wells: 400 mg/ft2

FLAA: Flame Atomic Absorption, GFAA: Graphite Furnace Atomic Absorption, HNO3: Nitric Acid, HUD: Housing & Urban Development Administration, OSHA: Occupational Safety & Health Administration, L: Liter, mg: milligram, m3: cubic meter, mg: micrograms, ppm: parts per million, mg/ft2: micrograms of sample per square feet

NOTE: All above values may change from one locality to another, and may
become updated. A local environmental agency or consultant should
be contacted for the latest updates

 

© Micro Analytical Laboratories, Inc. All Rights Reserved